China Factory Split Air Conditioner Cooling Heating Domestic Hot Water 14kw Air Source R32 Water Source Heat Pump

China Factory Split Air Conditioner Cooling Heating Domestic Hot Water 14kw Air Source R32 Water Source Heat PumpR32 Spilt DC Inverter Air to Water Heat Pump, Heating Cooling and Hot WaterProduct DescriptionOUTES :AHbS4VR3H & AHbS6VR3H &AHbS8VR3H & AHbS10VR3H & AHbS12VR3H & AHbS14VR3H & AHbS16VR3H& AHbS12VR3X & AHbS14VR3X & AHbS16VR3XDomestic Sanitary Hot Water CoolingHeatingCooling+DHWHeating+DHWDC Inverter Compressor Workable at -25ºCAir to water heat pump split type house heating system heat pump whole house application diagram Product ParametersModel AHbS4VR3HAHbS6VR3HAHbS8VR3HAHbS10VR3HAHbS12VR3HAHbS14VR3HAHbS16VR3HAHbS12VR3XAHbS14VR3XAHbS16VR3XPower Supply/220V~240V/1N/50Hz220V~240V/1N/50Hz220V~240V/1N/50Hz220V~240V/1N/50Hz220V~240V/1N/50Hz220V~240V/1N/50Hz220V~240V/1N/50Hz380V~415V/3N/50Hz380V~415V/3N/50Hz380V~415V/3N/50HzHeating*(A7ºC/W35ºC)Max. Heating CapacitykW4.2 6.4 8.0 10.0 12.1 14.5 15.9 12.1 14.5 15.9 Heating Input PowerkW0.82 1.28 1.63 2.02 2.44 3.15 3.53 2.44 3.15 3.53 Heating**(A7ºC/W55ºC)Max. Heating CapacitykW4.4 6.0 7.5 9.5 11.9 13.8 16.0 11.9 13.8 16.0 Heating Input PowerkW1.49 2.03 2.36 3.06 3.90 4.68 5.61 3.90 4.68 5.61 Cooling(A35ºC/W7ºC)Max. Cooling CapacitykW4.7 7.0 7.5 8.2 11.5 12.4 14.0 11.5 12.4 14.0 Cooling Input PowerkW1.36 2.33 2.22 2.52 4.18 4.96 5.60 4.18 4.96 5.60 Outdoor UnitCompressor/Twin RotaryTwin RotaryTwin RotaryTwin RotaryTwin RotaryTwin RotaryTwin RotaryTwin RotaryTwin RotaryTwin RotaryNoise(Sound Power Level)dB(A)≤56≤58≤59≤60≤64≤65≤68≤64≤65≤68Net Weightkg62627878959595105105105Net Dimension((L×W×H)mm1045×405×7701045×405×770995×390×1015995×390×1015995×390×1015995×390×1015995×390×1015995×390×1015995×390×1015995×390×1015Packing Dimension(L×W×H)mm1170×520×8901170×520×8901145×510×11601145×510×11601145×510×11601145×510×11601145×510×11601145×510×11601145×510×11601145×510×1160Indoor UnitHeat Exchanger/PlatePlatePlatePlatePlatePlatePlatePlatePlatePlateElectric HeaterkW3333333999Rated Water Flowm3/h0.721.11.381.722.082.492.732.082.492.73Noise(Sound Power Level)dB(A)≤40≤40≤42≤42≤43≤43≤43≤43≤43≤43Net Weightkg45454646484848484848Net Dimension(L×W×H)mm470×790×270470×790×270470×790×270470×790×270470×790×270470×790×270470×790×270470×790×270470×790×270470×790×270Packing Dimension(L×W×H)mm550×960×340550×960×340550×960×340550×960×340550×960×340550×960×340550×960×340550×960×340550×960×340550×960×340Max. Water Outlet TemperatureºC60606060606060606060Range of Working OperationºC-25~46-25~46-25~46-25~46-25~46-25~46-25~46-25~46-25~46-25~46Refrigerant/ R32  R32  R32  R32  R32  R32  R32  R32  R32  R32 ERP Level (35ºC)/A+++A+++A+++A+++A+++A+++A+++A+++A+++A+++ERP Level (55ºC) A++A++A++A++A++A++A++A++A++A++Container Loading(20'/40'H)Sets44/92/10444/92/10434/74/7534/74/7534/74/7534/74/7534/74/7534/74/7534/74/7534/74/75Remark:1.Testing Condition:Heating*: Ambient Temp.(DB/WB):7ºC/6ºC,Water Temp.(In/Out):30ºC/35ºC.Heating**: Ambient Temp.(DB/WB):7ºC/6ºC,Water Temp.(In/Out):47ºC/55ºC.Cooling : Ambient Temp.(DB/WB):35ºC/24ºC,Water Temp.(In/Out):12ºC/7ºC.2.The above data test reference EN14825:2016,EN14511:2011,EN12102:2008,(EU) No 811:2013,(EU) No 813:2013.3.The data above is only for reference, and  might be changed without prior notice.  Detailed Photos  Other recommendationsAbout OUTESOUTES was established in 2 0 0 6 with an industry park of 500,000m2, specializing in sales, R&D and manufacturing air conditioner, Cooling & Heating heat pump, Hot Water heat pump, Swimming Pool heat pump, Commercial heat pump, Fan Coils, Air Ventilation Unit, Water Purification Equipment and Pressure Water Tank.OUTES has reputation in domestic market. With 3000 distributors, 1000 After-sales Service Center and 10 local warehouse.Production LineTesting CentralTesting Central2007,we set up the 1st testing room, until now, we have 50+laboratories. The Testing Center is covered 8000m2 and the total investment reach to 50,000,000RMB. We have 350+ engineers working here now.2019, we got the approval from CNAS, TUV and BV. So it's more easy for us to test the products exporting to different countries now!We can test the performance, safety, life, noises, stress, transportation and all the other test we need for our products. The products we can test including Hot Water Heat Pump, Chillers, gas system Central Air conditioners, water system Central Air Conditioners, Swimming Pool Heat Pump, Dryers, Air Ventilation Unit and Water Purification Unit. The test capacity from 1 Horse Power to 200 Horse Power for a single Module Machine. The ambient test condition can be from -35ºC to 60ºC.We can test the performance, safety, life, noises, stress, transportation and all the other test we need for our products. The products we can test including Hot Water Heat Pump, Chillers, gas system Central Air conditioners, water system Central Air Conditioners, Swimming Pool Heat Pump, Dryers, Air Ventilation Unit and Water Purification Unit. The test capacity from 1 Horse Power to 200 Horse Power for a single Module Machine. The ambien