Jdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer

Product DescriptionJDZ9-35 series of indoor voltage transformer, which is the epoxy resin casting,  fully enclosed post structure. It's rated frequency 50Hz or 60Hz, rated voltage of power system up to 35kV(40.5kV), for measuring current,  electric energy and relay protection. The iron core and windings of the voltage current are casting together. The types  of JDZ9-35 arid JDZF9-35 are single-phase transformers connected between phases to phase. The JDZF9-35 has two secondary  windings and it has a energy measuring from voltage monitoring and relay protecting separately,  which is made of cold rolled silicon steel sheet. This voltage transformer conforms to IEC60044-2 and GB1207-2006  standard.Model DescriptionTechinical parameters and Structure dimensionsProduct features and scope of useThis series of voltage transformers is of epoxy resin casting pillar type fully enclosed structure. The iron core and  the winding are cast into one body,  and there is a mounting plate at the bottom. JDZ9-35 is single-phase and connected to the opposite phase. That is,  the energy measurement and voltage monitoring are separated. JDZX9-35 is single-phase, connected to the ground,  the primary A terminal is connected to the phase line,  and the N terminal is grounded. JDZXF9-35 has three secondary windings, that is, the energy measurement,  voltage monitoring and relay protection are separated. . JDZX9-35G is a fully insulated structure,  the primary A terminal is connected to the phase line,  and the N terminal is grounded. JDZXF9-35G has three secondary windings, that is, energy measurement,  voltage monitoring and relay protection are separated.It is resistant to dirt and moisture,  and is also suitable for use in tropical areas. The transformer does not require special maintenance,  but only needs to remove the surface dirt regularly. Since the transformer is fully enclosed and cast insulation,  it is small in size and light in weight,  suitable for installation in any position and direction. . A terminal box is installed at the secondary outlet terminal.  There are three outlet terminal holes on the box,  and the secondary wires can be drawn from different directions. The wiring is convenient, safe and reliable,  and can realize anti-theft measures.Ambient temperature:-10ºC-+40ºCRelative humidity:The average humidity of a day should be no more than 95%. The average humidity of a month should be no  more than 90%.Earthquake intensity: not exceed 8 degrees.Saturated vapor pressure the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no moreThan1.8 Kpa.The height above sea level:≤1000 m (Except special requirements)It should be installed in the places without fire, explosion, serious filth, and chemical erosion and violent vibration.Ordering notice1. Provide wiring scheme diagram, application and system diagram, rated voltage, rated current, etc.2. Requirements for control, measurement and protection functions and other locking and automatic devices.3. When the transformer is used in special environmental conditions, it should be explained in detail when ordering.4. When other or more accessories and spare parts are needed, the type and quantity should be proposed.Product detailsProduct real shotA coner of the production workshopProduct packagingProduct application use /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1